HPAPI Containment, From Exposure Limit to Verified Isolator
How limits, bands, isolators and verification fit together, and where each is debated in Rome on 21 to 22 April 2027.
- Limits firstOELs and HBELs on Day 1 morning
- OEB 5 to OEB 7A full engineering session
- Flexible vs rigidIsolators compared on Day 2
- Proof that it worksHygiene and cleaning validation
- 21 to 22 April 2027, Rome
- 60+ companies represented
Exhibit Your Containment Technology
Engineering, EHS and validation leads are in the room. Leave your details for the prospectus.


AM Instruments




Containment Starts With the Limit, Not the Equipment
A toxicologist sets the exposure limit. The limit decides the band, the band sets the controls, and only then is equipment chosen.
- Toxicology data
- OEL or HBEL
- OEB band
- Control strategy
- Equipment and proof
Pick a Band, See the Containment Step Up
Cut-offs differ between companies and some add bands above OEB 5. The right controls for a process always come from a risk assessment.
OEB 1 to 2: Lower potency
Good manufacturing practice and general ventilation, with local exhaust where dust is released.
- General room ventilation
- Local exhaust at dust points
- Standard PPE
OEB 3: Moderate potency
Partial containment such as ventilated enclosures and downflow booths, with PPE as a second line.
- Ventilated enclosures
- Downflow booths
- PPE as back-up
OEB 4: High potency
Closed transfers and engineered containment for every open handling step.
- Split butterfly valves
- Closed transfer systems
- Isolators for open steps
OEB 5 and above: Highly potent to ultra-potent
Isolator-based, closed processing throughout, with verified performance. ADC payloads usually sit here.
- Isolators throughout
- Closed processing end to end
- Verified containment performance
Flexible or Rigid? Flip Between Them
Both can reach high containment. The choice turns on run length, product changes and cleaning. Day 2 compares them at 10:10.
General characteristics. Performance depends on design, operation and verification for each application.
Three Ways to Show the Containment Works

Performance testing
Surrogate powder tests, often to the ISPE SMEPAC guide, measure what escapes under real operation.

Occupational hygiene
Air and surface monitoring show operators stay below the limit. Praevena covers an ADC plant on Day 2.

Cleaning validation
In shared suites, residues must fall below health-based limits before the next product runs.
Eight Containment Talks Across Both Days
- Day 1, 10:10Robust OELs, HBELs and PDEs for next-generation molecules
- Day 1, 12:25ADC payload manufacturing: containment and safety
- Day 1, 16:00Engineering for OEB 5 to OEB 7 environments
- Day 2, 09:40Containment technologies for ultra-potent compounds
- Day 2, 10:10Flexible vs rigid isolators: performance and cost
- Day 2, 11:25Occupational hygiene aspects of an ADC plant
- Day 2, 11:55Cleaning validation for HPAPI and ADC lines
- Day 2, 16:00Automation and robotics in high containment
- Jeremy WienExyte
Silke BüchlPraevena AG
Jana NunićNovartis
Carla LandolfiToxHub
Six Terms, Tap or Hover to Flip
- OEL
- Occupational exposure limit: the airborne level a worker can meet over a shift without harm.
- HBEL
- Health-based exposure limit, derived from toxicology, for workers and cross-contamination.
- PDE
- Permitted daily exposure: the daily dose safe for a patient over a lifetime. Sets cleaning limits.
- OEB
- Occupational exposure band: compounds with similar limits, matched to one level of containment.
- SMEPAC
- The ISPE good practice guide for testing how well equipment contains particles.
- CPT
- Containment performance target: the emission level equipment must stay below.
Containment Makers at the 2026 Edition
Engineering, EHS, industrial hygiene and validation leads are in the room for both days. On the 2026 participant list:
- CSV Containment
- SKAN
- FPS Pharma
- Lugaia
- Syntegon Telstar
- Hosokawa Alpine
- Howorth Air Technology
- DEC Group
- Hecht
- De Dietrich Process Systems
Source: 2026 post-event report. Also read containment and isolator suppliers and the HPAPI conference overview.
Containment Questions
What is HPAPI containment?
The engineering controls, procedures and protective equipment that keep workers, patients and the environment safe from highly potent APIs during manufacture.
What is an OEB?
An occupational exposure band groups compounds with similar limits so each band can be matched to a containment level. Cut-offs vary between companies.
When is an isolator needed?
Usually for open handling at OEB 4 and above, but the decision comes from a risk assessment of the specific process.
Which containment sessions are on the 2027 programme?
OEB 5 to OEB 7 engineering, ultra-potent containment, flexible vs rigid isolators, ADC plant hygiene, cleaning validation and automation.
Can containment suppliers exhibit?
Yes. Exhibitor and sponsor packages with a stand are listed in the prospectus, and meetings-only options exist for teams without a stand.
Reach the Teams Who Buy Containment
Tell us what you want out of the summit and we will send the full prospectus, plus a recommendation on the package that fits.








Silke Büchl
Jana Nunić
Carla Landolfi